Solar Calculator Canada

Solar Power Calculator for Swan River, Manitoba, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Swan River
  • GPS Coordinates: 52.105833, -101.26667
  • Elevation: 340 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Swan River: 43o
  • Average yearly irradiance: 1464.99 kWh/m2
  • Average yearly power output: 123858 kWh
Sun Path Swan River

Average yearly irradiance delivered by the Sun in Swan River is 1464.99/kWh/m2 at the optimal panel slope of 43o. After taking all losses into account, you can expect about 123858 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 43o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 1.73 53.48
February 2.6 72.68
March 3.69 114.53
April 5.44 163.18
May 5.64 174.76
June 5.59 167.74
July 6.11 189.33
August 5.62 174.08
September 4.79 143.56
October 3.34 103.43
November 2.02 60.53
December 1.54 47.69
Total yearly 1464.99

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 164.62 5103.07
February 243.61 6821.09
March 330.65 10250.2
April 466.32 13989.5
May 466.99 14476.6
June 450.25 13507.5
July 484.72 15026.4
August 449.2 13925.3
September 395.01 11850.3
October 287.49 8912.21
November 182.59 5477.59
December 145.75 4518.34
Total yearly 123858

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Swan River solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 102.21 3168.43
February 174.71 4891.77
March 276.94 8585.05
April 441.03 13231
May 485.59 15053.4
June 487.17 14615
July 513.98 15933.3
August 442.89 13729.7
September 345.01 10350.3
October 219.77 6812.74
November 119.73 3591.99
December 85.96 2664.85
Total yearly 112627

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 116.18 3601.5
February 190.78 5341.93
March 291.13 9025.17
April 451.63 13549
May 487.67 15117.9
June 485.72 14571.5
July 514.69 15955.5
August 449.76 13942.6
September 359.36 10780.7
October 236.05 7317.53
November 133.93 4017.93
December 99.21 3075.53
Total yearly 116297

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 128.94 3997.15
February 205.23 5746.41
March 303.35 9403.78
April 459.58 13787.3
May 487.52 15113
June 481.8 14453.9
July 512.96 15901.6
August 454.07 14076.3
September 371.41 11142.3
October 250.57 7767.81
November 146.88 4406.54
December 111.38 3452.73
Total yearly 119249

Swan River Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 140.47 4354.68
February 218.03 6104.74
March 313.56 9720.33
April 464.92 13947.5
May 484.99 15034.8
June 476.23 14286.8
July 508.44 15761.5
August 455.91 14133.1
September 381.11 11433.3
October 263.3 8162.25
November 158.56 4756.7
December 122.43 3795.41
Total yearly 121491

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.75% angle of incidence loss and -3.4% temperature and irradiance loss. This totals to about -15.45%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations:

CharlottetownQuebecSt. John'sVictoriaWinnipegReginaEdmontonIqaluitFort SevernKangirsukFort NelsonNainZama CityWollaston LakeFond-du-LacBlack LakeWollaston LakeHalifaxMurray RiverTofinoMurdochville